30 research outputs found

    A novel receive-only liquid nitrogen (LN2)-cooled RF coil for high-resolution in vivo imaging on a 3-Tesla whole-body scanner

    Get PDF
    The design and operation of a receive-only liquid nitrogen (LN2)-cooled coil and cryostat suitable for medical imaging on a 3-T whole-body magnetic resonance scanner is presented. The coil size, optimized for murine imaging, was determined by using electromagnetic (EM) simulations. This process is therefore easier and more cost effective than building a range of coils. A nonmagnetic cryostat suitable for small-animal imaging was developed having good vacuum and cryogenic temperature performance. The LN2-cooled probe had an active detuning circuit allowing the use with the scanner's built-in body coil. External tuning and matching was adopted to allow for changes to the coil due to temperature and loading. The performance of the probe was evaluated by comparison of signal-to-noise ratio (SNR) with the same radio-frequency RF) coil operating at room temperature (RT). The performance of the RF coil at RT was also benchmarked against a commercial surface coil with a similar dimension to ensure a fair SNR comparison. The cryogenic coil achieved a 1.6- to twofold SNR gain for several different medical imaging applications: For mouse-brain imaging, a 100-mu m resolution was achieved in an imaging time of 3.5 min with an SNR of 25-40, revealing fine anatomical details unseen at lower resolutions for the same time. For heavier loading conditions, such as imaging of the hind legs and liver, the SNR enhancement was slightly reduced to 1.6-fold. The observed SNR was in good agreement with the expected SNR gain correlated with the loaded-quality factor of RF coils from the EM simulations. With the aid of this end-user-friendly and economically attractive cryogenic RF coil, the enhanced SNR available can be used to improve resolution or reduce the duration of individual scans in a number of biomedical applications

    Intramuscular fat in ambulant young adults with bilateral spastic cerebral palsy

    Get PDF
    BACKGROUND: It is known that individuals with bilateral spastic cerebral palsy (BSCP) have small and weak muscles. However, no studies to date have investigated intramuscular fat infiltration in this group. The objective of this study is to determine whether adults with BSCP have greater adiposity in and around their skeletal muscles than their typically developing (TD) peers as this may have significant functional and cardio-metabolic implications for this patient group. METHODS: 10 young adults with BSCP (7 male, mean age 22.5 years, Gross Motor Function Classification System (GMFCS) levels I-III), and 10 TD young adults (6 male, mean age 22.8 years) took part in this study. 11 cm sections of the left leg of all subjects were imaged using multi-echo gradient echo chemical shift imaging (mDixon). Percentage intermuscular fat (IMAT), intramuscular fat (IntraMF) and a subcutaneous fat to muscle volume ratio (SF/M) were calculated. RESULTS: IntraMF was higher with BSCP for all muscles (p = 0.001-0.013) and was significantly different between GMFCS levels (p < 0.001), with GMFCS level III having the highest IntraMF content. IMAT was also higher with BSCP p < 0.001). No significant difference was observed in SF/M between groups. CONCLUSION: Young adults with BSCP have increased intermuscular and intramuscular fat compared to their TD peers. The relationship between these findings and potential cardio-metabolic and functional sequelae are yet to be investigated

    Personal exposure to static and time-varying magnetic fields during MRI procedures in clinical practice in the UK

    Get PDF
    Background: MRI has developed into one of the most important medical diagnostic imaging modalities, but it exposes staff to static magnetic fields (SMF) when present in the vicinity of the MR system, and to radiofrequency and switched gradient electromagnetic fields if they are present during image acquisition. We measured exposure to SMF and motion-induced time-varying magnetic fields (TVMF) in MRI staff in clinical practice in the UK to enable extensive assessment of personal exposure levels and variability, which enables comparison to other countries. Methods: 8 MRI facilities across National Health Service sites in England, Wales and Scotland were included, and staff randomly selected during the days when measurements were performed were invited to wear a personal MRI-compatible dosimeter and keep a diary to record all procedures and tasks performed during the measured shift. Results: 98 participants, primarily radiographers (71%) but also other healthcare staff, anaesthetists and other medical staff were included, resulting in 149 measurements. Average geometric mean peak SMF and TVMF exposures were 448 mT (range 20–2891) and 1083 mT/s (9–12 355 mT/s), and were highest for radiographers (GM=559 mT and GM=734 mT/s). Time-weighted exposures to SMF and TVMF (GM=16 mT (range 5–64) and GM=14 mT/s (range 9–105)) and exposed-time-weighted exposures to SMF and TVMF (GM=27 mT (range 11–89) and GM=17 mT/s (range 9–124)) were overall relative low—primarily because staff were not in the MRI suite for most of their shifts—and did not differ significantly between occupations. Conclusions: These results are comparable to the few data available from the UK but they differ from recent data collected in the Netherlands, indicating that UK staff are exposed for shorter periods but to higher levels. These data indicate that exposure to SMF and TVMF from MRI scanners cannot be extrapolated across countries

    Physics and medicine: a historical perspective

    No full text

    Journal of Cardiovascular Magnetic Resonance BioMed Central Poster presentation Positive visualization of nitinol stent-grafts by postprocessing

    No full text
    The emergence of new MR-compatible nitinol-based stent-grafts [1] allows follow-up MRI of patients with these devices to assess stent-graft and wall apposition, or monitoring endovascular aneurysm repair. In particular